ACMP1MODE=DISABLE, ACMP0MODE=DISABLE, WARMUPMODE=NORMAL
Peripheral Control Register
| DACCH0EN | VDAC CH0 Enable |
| DACCH1EN | VDAC CH1 Enable |
| DACCH0DATA | VDAC CH0 Data Selection |
| DACCH1DATA | VDAC CH1 Data Selection |
| DACSTARTUP | VDAC Startup Configuration |
| DACCONVTRIG | VDAC Conversion Trigger Configuration |
| ACMP0MODE | ACMP0 Mode 0 (DISABLE): LESENSE does not control ACMP0 1 (MUX): LESENSE controls the input mux (POSSEL) of ACMP0 2 (MUXTHRES): LESENSE controls the input mux (POSSEL) and the threshold value (VDDLEVEL) of ACMP0 |
| ACMP1MODE | ACMP1 Mode 0 (DISABLE): LESENSE does not control ACMP1 1 (MUX): LESENSE controls the input mux (POSSEL) of ACMP1 2 (MUXTHRES): LESENSE controls the input mux and the threshold value (VDDLEVEL) of ACMP1 |
| ACMP0INV | Invert Analog Comparator 0 Output |
| ACMP1INV | Invert Analog Comparator 1 Output |
| ACMP0HYSTEN | ACMP0 Hysteresis Enable |
| ACMP1HYSTEN | ACMP1 Hysteresis Enable |
| WARMUPMODE | ACMP and VDAC Duty Cycle Mode 0 (NORMAL): The analog comparators and VDAC are shut down when LESENSE is idle 1 (KEEPACMPWARM): The analog comparators are kept powered up when LESENSE is idle 2 (KEEPDACWARM): The VDAC is kept powered up when LESENSE is idle 3 (KEEPACMPDACWARM): The analog comparators and VDAC are kept powered up when LESENSE is idle |